Introduction
The folding and inserting system can be equipped with reading. This allows the system to
read special codes that have been printed on the documents. These codes contain
information about the processing of the sheets. The following code type is available:
1-track basic or advanced OMR: Optical Mark Recognition
Depending on the settings, the code tells the system if:
The document set is complete
Enclosures must be added to the set
The system must stop
The set is complete (no pages are missing)
The sheets with the printed code are placed in a feeder. Depending on the programmed
code, the other feeders can be used as selective feeders to add enclosures.
In case of a Z-fold, the address has to be printed on the last page of the set (see Document
orientation on page 54 for the code position). With the other fold types, the first sheet of a
set always contains the address. A full length code is printed on every sheet of a set. The
code must appear at the same location on every page regardless of the actual code length.
The code on the last sheet of the set contains the insert instruction. The other sheets carry
the accumulate instruction. If a parity check is used with OMR, this is checked on each
sheet.